Change Out Guide
The following is a reliable guide for replacing existing high energy using lamps, globes and bulbs.
All replacement items should be available for purchase, however any lights not in stock or not listed can be custom ordered at wholesale prices.
Please email sales@littil.com.au for a quote
Old Lamp | Rated Watts | Total Watts Used | New LED lamp | Total Watts Used | Volts | Comments |
Glass MR16 50W 60° Quartz Halogen 2-5,000 hrs |
35 | 50 | MR16 6W 60° 50,000 hrs |
6 | 12 | May run on an old transformer. Some are dimmable, check specs. Only dimmable on LED driver. |
Glass MR16 50W 60° Quartz Halogen 2-5,000 hrs |
50 | 65 | MR16 9W 60° CREE 50,000 hrs |
9 | 12 | May run on old transformer. Some are dimmable, check specs. Only dimmable on LED driver. |
Glass GU10 50W 60° Quartz Halogen 2-5,000 hrs |
25 | 35 | GU10 6W 60° COB 50,000 hrs |
6 | 240 | Plug straight into GU10 socket. Performance reduced substantially if dimmable. |
Glass GU10 50W 60° Quartz Halogen 2-5,000 hrs |
50 | 60 | GU10 9W 60° COB 50,000 hrs |
9 | 240 | Plug straight into GU10 socket. Performance reduced substantially if dimmable. |
Par30 50W Halogen Flood 2-5,000 hrs |
50 | 50 | Par 30 17W 120° 50,000 hrs |
12 | 240 | Plug straight in to E27 socket. Must be 100mm plus long. |
Par30 70W Metal Halide Flood / Spot 5-7,500 hrs |
70 | 95 | Par 30 17W 120° 50,000 hrs |
17 | 240 | Plug straight in to E27 socket. Must be 100mm long plus. |
PLC Compact Fluoro 18 to 36W 5-7,000 hrs |
18 | 25 | LED G24 8W 50,000 hrs |
8 | 240 | Plug straight in to G24 socket and bypass control gear |
T8 fluoro lamp with external ballast 36W – 1200 mm 5-10,000 hrs |
36 | 42 | T8 15W LED Tube 20,000 hrs |
15 | 240 | Essential fixture upgrade. Bypass ballast. Must remove capacitor. |